Monday, June 17, 2019

The ICH publishes E8(R1) Draft Guideline for comment

The ICH E8(R1) draft Guideline on General Considerations for Clinical Trials reached Step 2b of the ICH Process in May 2019 and has entered the public consultation period. The modernization of ICH E8 is the first step towards the GCP Renovation initiated in 2017.

The International Council for Harmonisation, ICH, is proposing a modernization of ICH E8 in order to incorporate the most current concepts achieving fit-for-purpose data quality as one of the essential considerations for all clinical trials. The revision proposes to:
  • identify a basic set of critical-to-quality factors that can be adapted to different types of trials to support the meaningfulness and reliability of trial results and to protect human subjects;
  • address a broader range of trial designs and data sources;
  • provide an updated cross-referencing of all other relevant ICH Guidelines that should be referred to when planning clinical studies.
Topicsa and structure of the ICH draft
The draft document covers the following topics:
  • GENERAL PRINCIPLES, including the protection of clinical study subjects, scientific approach in clinical study design, conduct, and analysis, patient input into study design.
  • DESIGNING QUALITY INTO CLINICAL STUDIES, e.g. by applying Quality by Design (QbD), including processes that ensure Data Integrity (DI), critical-to-quality factors & approaches to identifying the critical-to-quality factors.
  • DRUG DEVELOPMENT PLANNING for non-clinical studies & clinical studies, including quality & formulation of Investigational Medicinal Products (IMPs), & feasibility.
  • DESIGN ELEMENTS FOR CLINICAL STUDIES, including study design & study data.
  • STUDY CONDUCT AND REPORTING, including training, data management, access to interim data, safety monitoring, Data Monitoring Committee (DMC) & clinical study reports.
  • CONSIDERATIONS IN IDENTIFYING CRITICAL-TO-QUALITY FACTORS.
In addition, the draft document comprises 3 Annexes:
  • Annex 1: TYPES OF STUDIES (i.e. Non-clinical testing, Human Pharmacology, Exploratory, Confirmatory, Post-Approval)
  • Annex 2: ICH E FAMILY OFGUIDELINES
  • Annex 3: SELECTED EXAMPLES OF CRITICAL-TO-QUALITY FACTORS, including randomization, blinding/ masking, data quality, procedures supporting study endpoints and Data Integrity (DI), informed consent, training, data recording and reporting, data monitoring and management, statistical analysis, and delegation of sponsor responsibilities.
More Information is available on ICH´s Efficacy Guidelines page and in the draft Guideline GENERAL CONSIDERATIONS FOR CLINICAL STUDIES E8(R1).

Friday, May 31, 2019

The ICH E8(R1) reaches Step 2b of the ICH Process

The ICH E8(R1) draft Guideline on General Considerations for Clinical Trials reached Step 2b of the ICH Process in May 2019 and has entered the public consultation period.

Further information can be found on the E8(R1) page, including the Step 2 draft Guideline for download.

Saturday, March 30, 2019

ICH Advances Revised Guideline on Elemental Impurities

The internationally harmonized guideline for a risk-based approach on assessing and controlling elemental impurities in drug products entered the final implementation phase.

ICH Q3D(R1) Guideline for Elemental Impurities, developed via the International Council for Harmonisation (ICH), reached the fourth out of five steps in ICH’s process of regulatory harmonization last week, moving toward implementation of the revised guideline. The guideline was first recommended for adoption by the ICH member regulatory authorities in 2014 but was re-released for public consultation in May 2018 due to the revision of the Permitted Daily Exposure (PDE) level for Cadmium by inhalation.

The Q3D(R1) quality guideline establishes a harmonized platform intended to limit elemental impurities in drug products by conducting assessments and employing a control strategy based on the risk management principles previously set forth via ICH Q9: Quality Risk Management. It also defines the PDEs for 24 elemental impurities for drug products administered orally, parentally and by inhalation.

The revised Cadmium inhalation PDE is 3.4 versus the 1.7 PDE ICH recommended for adoption in 2014.

Earlier adoption and regional implementation of the Q3D(R1) ranged between 2014 and 2016 among the ICH regulatory bodies, which include the European Medicines Agency, Japan’s Ministry of Health, Labour and Welfare, the US Food and Drug Administration (FDA), Health Canada and Swissmedic.

FDA finalized its addendum to the ICH elemental impurities guidelines last August. With the July 2018 draft version of this FDA guidance document, the agency had explained that the revision to the previous Cadmium inhalation PDE was needed to “correct a calculation error” and it had been revised “based on a modifying factor approach that is consistent with the oral and parenteral PDE calculations.”

ICH Q3D(R1) Guideline for Elemental Impurities